Total dynamic head, pipe friction, settling velocity, head and efficiency de-rating for slurry and dense medium, pump speed, NPSH, absorbed power, motor size and running amps.
From the pump supplier's curve at one speed. Leave blank to use a fixed efficiency.
| Flowm³/h | Headm | Efficiency% | NPSHrm |
|---|
Register once, free, to see the head, power and motor for your own duty.
Already registered?
| Item | Basis | Value | Unit |
|---|
Slurry: Sm = 100/(Cw/S + 100 − Cw), Cv = Cw·Sm/S. Head ratio HR = ER = 1 − 0.000385·(S − 1)·(1 + 4/S)·Cw·ln(d50/0.0227), which reproduces the classic Warman HR chart. For dense medium, HR is taken for the medium only and the ore or coal is ignored, as is usual practice.
Settling: Durand VL = FL·√(2gD(S − Sl)/Sl), FL from the Warman charts for widely or closely graded solids. In dense medium the carrier is the medium, so Sl is the medium RD.
Friction: Darcy-Weisbach with Colebrook, fittings by K·V²/2g. Slurry friction follows the Warman categories: 100–300 µm solids equal water friction above 1.3 VL and reach a minimum at 0.7 VL; coarser solids take 1.1 × water.
Power: P = ρm·g·Q·H / (ηw·ER). Running current I = Pin / (√3·V·pf).
Long-radius bend 0.3 · short elbow 0.75 · 45° bend 0.2 · tee branch 1.0 · tee run 0.4 · knife-gate or full-bore valve 0.2 · butterfly valve 0.5 · check valve 2.0 · pinch valve 0.4 · reducer 0.1 · entry 0.5 · exit 1.0
Steady, fully turbulent flow of Newtonian slurries and medium. Viscous, non-settling (fine, high-yield) slurries, froth and long-distance pipelines need rheology tests or a specialist. Pump wear, speed limits, seal water and mechanical ratings are not checked. Confirm the selection with the pump supplier.