RED DUNE
Red Dune · Process Engineer Toolkit

Slurry & Water Pump Calculator

Total dynamic head, pipe friction, settling velocity, head and efficiency de-rating for slurry and dense medium, pump speed, NPSH, absorbed power, motor size and running amps.

A RED DUNE TOOL · v0.1
You're viewing an example duty. Enter your own pump duty. Free registration unlocks your results.

Duty

Example data loaded
Suction side
Discharge side
Pump curve (clear water)

From the pump supplier's curve at one speed. Leave blank to use a fixed efficiency.

Flowm³/hHeadmEfficiency%NPSHrm
Motor and drive

Pump duty

System curve (slurry)System curve (clear water)Pump on slurry at required speedLimiting settling velocity

Calculation

ItemBasisValueUnit

Method

Slurry: Sm = 100/(Cw/S + 100 − Cw), Cv = Cw·Sm/S. Head ratio HR = ER = 1 − 0.000385·(S − 1)·(1 + 4/S)·Cw·ln(d50/0.0227), which reproduces the classic Warman HR chart. For dense medium, HR is taken for the medium only and the ore or coal is ignored, as is usual practice.

Settling: Durand VL = FL·√(2gD(S − Sl)/Sl), FL from the Warman charts for widely or closely graded solids. In dense medium the carrier is the medium, so Sl is the medium RD.

Friction: Darcy-Weisbach with Colebrook, fittings by K·V²/2g. Slurry friction follows the Warman categories: 100–300 µm solids equal water friction above 1.3 VL and reach a minimum at 0.7 VL; coarser solids take 1.1 × water.

Power: P = ρm·g·Q·H / (ηw·ER). Running current I = Pin / (√3·V·pf).

Reading the results

  • Velocity below VL: solids settle and the line can block. Use a smaller pipe or more flow.
  • Water-equivalent head H/HR is the head to read on the clear water pump curve; the pump speed comes from there.
  • NPSHa below NPSHr + 1 m: risk of cavitation. Raise the sump, shorten the suction or lower the speed.
  • Coarse or high-concentration slurries (over 40% by mass, or coarse at over 20%) can have up to two to three times the estimated friction: keep speed and power in reserve.

Fitting K values

Long-radius bend 0.3 · short elbow 0.75 · 45° bend 0.2 · tee branch 1.0 · tee run 0.4 · knife-gate or full-bore valve 0.2 · butterfly valve 0.5 · check valve 2.0 · pinch valve 0.4 · reducer 0.1 · entry 0.5 · exit 1.0

Limitations

Steady, fully turbulent flow of Newtonian slurries and medium. Viscous, non-settling (fine, high-yield) slurries, froth and long-distance pipelines need rheology tests or a specialist. Pump wear, speed limits, seal water and mechanical ratings are not checked. Confirm the selection with the pump supplier.

References

  • Warman International: Slurry Pumping Manual.
  • Metso: Slurry Pump Basic handbook.
  • Hydraulic Institute ANSI/HI 12.1–12.6: Rotodynamic slurry pumps.
  • Durand (1953); Wilson, Addie & Clift: Slurry Transport Using Centrifugal Pumps.
  • Crane TP-410: Flow of fluids through valves, fittings and pipe.